Alert description

The drive interface (DI) electronic control unit (ECU) detects that the high voltage processor (HVP) controller area network (CAN) node is missing (MIA).

Potential impact

The DI ECU is unable to monitor the state of the HVP, and active discharge may turn on.

Set condition

The DI ECU is not receiving the expected CAN communication from the HVP, and considers it irrational or MIA.

Clear condition

The DI ECU receives the required CAN messages from the HVP.

Signals to check

These diagnostic fields are associated with DIR_a119. Check the alert's Payload in Service Mode Plus for available values.

Signal Unit
Hvp Faults DIR_a119_hvpFaults —

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of DIR_a119.