Skip to content

DIR_a103 — Low Flow

Full alert identifier: DIR_a103_lowFlow

Message shown in the car

Power limited - OK to drive Schedule service

Alert description

Drive Inverter Warning: Low flow rate of fluid

Potential impact

Drive unit enters unit limp mode (see DI_a126_limpMode)

Set condition

Insufficient cooling to the drive inverter is detected

Clear condition

Cooling is sufficient and a drive cycle is executed

Signals to check

Open this alert in Service Mode Plus and review the Payload tab. Use the field names below to identify the values shown by your vehicle.

Signal Unit
Ambient Temp DIR_a103_ambientTemp C
Fluid Tor Delta T DIR_a103_fluidTorDeltaT C
Inverter Temp DIR_a103_inverterTemp C
Rms Current DIR_a103_rmsCurrent A
Sensor Temp Est DIR_a103_sensorTempEst C
Signal Unit
Fluid Implausible DIR_a103_fluidImplausible —
Low Flow Detected DIR_a103_lowFlowDetected —
No Flow Detected DIR_a103_noFlowDetected —

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of DIR_a103.

Browse all DIR alert codes