Skip to content

DIR_a064 — Torque Intervention

Full alert identifier: DIR_a064_torqueIntervention

Alert description

The torque production safety monitor has detected excess torque production and inhibited Drive Inverter (DIx) torque production for the remainder of the drive cycle.

Potential impact

The torque production safety monitor will inhibit torque and excess heat production for the remainder of the drive cycle.

Set condition

The torque production safety monitor has detected excess torque production and inhibited DIx torque production for the remainder of the drive cycle.

Clear condition

Begin a new drive cycle.

Signals to check

These diagnostic fields are associated with DIR_a064. Check the alert's Payload in Service Mode Plus for available values.

Signal Unit
Intervention Type DIR_a064_interventionType —
Torque Cmd State DIR_a064_torqueCmdState
0
SNA
6
Valid
8
Invalid
—

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of DIR_a064.

Browse all DIR alert codes