Skip to content

DIRER_a244 — Mech Safe State Applied

Full alert identifier: DIRER_a244_mechSafeStateApplied

Alert description

Alert for software trigger of mechanical safe state two-phase disconnect device.

Potential impact

The motor is permanently disabled.

Set condition

Software detects a shorted semiconductor switch. The alert log signals provide detailed trigger algorithm info.

Clear condition

Clears when low voltage (LV) power is removed from drive unit or a non-drive/drive cycle occurs

Signals to check

Open this alert in Service Mode Plus and review the Payload tab. Use the field names below to identify the values shown by your vehicle.

Signal Unit
Delay DIRER_a244_delay us
Ir Sensor V DIRER_a244_irSensorV V
Signal Unit
Desat High Side DIRER_a244_desatHighSide —
Desat Low Side DIRER_a244_desatLowSide —
Flyback Fault DIRER_a244_flybackFault —
Gate Drive IC Undervoltage DIRER_a244_gateDriveICUndervoltage —
Plausible Single Switch Short Only DIRER_a244_plausibleSingleSwitchShortOnly —
Post Short Test Failed DIRER_a244_postShortTestFailed —
Single Switch Short DIRER_a244_singleSwitchShort —
Uds Self Test DIRER_a244_udsSelfTest —

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of DIRER_a244.

Browse all DIRER alert codes