Skip to content

DIRER_a103 — Low Flow

Full alert identifier: DIRER_a103_lowFlow

Message shown in the car

Rear right motor power may be limited OK to drive - Schedule service

Alert description

Drive Inverter Warning: Low flow rate of fluid

Potential impact

Drive unit enters unit limp mode (see DI_a126_limpMode)

Set condition

Insufficient cooling to the drive inverter is detected

Clear condition

Cooling is sufficient and a drive cycle is executed

Signals to check

Open this alert in Service Mode Plus and review the Payload tab. Use the field names below to identify the values shown by your vehicle.

Signal Unit
Ambient Temp DIRER_a103_ambientTemp C
Fluid Tor Delta T DIRER_a103_fluidTorDeltaT C
Inverter Temp DIRER_a103_inverterTemp C
Rms Current DIRER_a103_rmsCurrent A
Sensor Temp Est DIRER_a103_sensorTempEst C
Signal Unit
Fluid Implausible DIRER_a103_fluidImplausible —
Low Flow Detected DIRER_a103_lowFlowDetected —
No Flow Detected DIRER_a103_noFlowDetected —

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of DIRER_a103.

Browse all DIRER alert codes