DIREL_a244 — Mech Safe State Applied
Full alert identifier: DIREL_a244_mechSafeStateApplied
Alert description
Alert for software trigger of mechanical safe state two-phase disconnect device.
Potential impact
The motor is permanently disabled.
Set condition
Software detects a shorted semiconductor switch. The alert log signals provide detailed trigger algorithm info.
Clear condition
Clears when low voltage (LV) power is removed from drive unit or a non-drive/drive cycle occurs
Signals to check
Open this alert in Service Mode Plus and review the Payload tab. Use the field names below to identify the values shown by your vehicle.
| Signal | Unit |
|---|---|
Delay
DIREL_
|
us |
Ir Sensor V
DIREL_
|
V |
| Signal | Unit |
|---|---|
Desat High Side
DIREL_
|
— |
Desat Low Side
DIREL_
|
— |
Flyback Fault
DIREL_
|
— |
Gate Drive IC Undervoltage
DIREL_
|
— |
Plausible Single Switch Short Only
DIREL_
|
— |
Post Short Test Failed
DIREL_
|
— |
Single Switch Short
DIREL_
|
— |
Uds Self Test
DIREL_
|
— |
Check other alerts
With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of DIREL_a244.