DIREL_a117 — Di MIA
Full alert identifier: DIREL_a117_diMIA
Alert description
The Drive Inverter (DIx) node is Missing in Action (MIA) on Controller Area Network (CAN) for one or more messages.
Potential impact
DIx may not be able to communicate with the High Voltage Processor (HVP).
Set condition
The DIx node is MIA on CAN for one or more messages. The DIx node or DIx may have a condition affecting functionality.
Clear condition
The DIx node resumes communication with CAN.
Signals to check
These diagnostic fields are associated with DIREL_a117. Check the alert's Payload in Service Mode Plus for available values.
| Signal | Unit |
|---|---|
Add Tc Limit
DIREL_
|
— |
Chassis Control
DIREL_
|
— |
Dix Command
DIREL_
|
— |
Loc Status
DIREL_
|
— |
Odometer Status
DIREL_
|
— |
Power
DIREL_
|
— |
Slave Command
DIREL_
|
— |
Slave Command 2
DIREL_
|
— |
Show 5 more fields
| Signal | Unit |
|---|---|
Speed
DIREL_
|
— |
System Status
DIREL_
|
— |
Temperature
DIREL_
|
— |
Torque
DIREL_
|
— |
Vehicle
DIREL_
|
— |
Check other alerts
With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of DIREL_a117.