Skip to content

DIF_a241 — System Thermally Limited

Full alert identifier: DIF_a241_systemThermallyLimited

Alert description

Drive Inverter Warning: Report current limited due to thermal temperatures for diagnostic purpose

Potential impact

No direct impact. Diagnostic message for thermal limitations of the system.

Set condition

DI reports that the stator or rotor temperature are high and current is limited below 200 Amps

Clear condition

current is above the threshold and not limited anymore due to rotor or stator temeprature after alert is set

Signals to check

Open this alert in Service Mode Plus and review the Payload tab. Use the field names below to identify the values shown by your vehicle.

Signal Unit
Rotor Max Magnet Temp DIF_a241_rotorMaxMagnetTemp degC
Stator End Winding Temp DIF_a241_statorEndWindingTemp degC

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of DIF_a241.