DIF_a024 — Self Test

Full alert identifier: DIF_a024_selfTest

Alert description

The Switch Off Path Test (SOPT) for Drive Unit has failed. The pathway between Drive Inverter (DIx) and Pedal Monitor (PM) torque measurements are different.

Potential impact

PM may not be able to shut down torque produced by Drive Unit.

Set condition

The Switch Off Path Test (SOPT) for Drive Unit has failed. The DIx and PM torque measurements are different. The pathway between DIx and PM may have a condition affecting functionality.

Clear condition

This alert is primarily intended for logging purposes. If this alerts repeatedly asserts, there may a condition affecting the DIx hardware.

Signals to check

Open this alert in Service Mode Plus and review the Payload tab. Use the field names below to identify the values shown by your vehicle.

Signal Unit
Ia DIF_a024_Ia A
Ib DIF_a024_Ib A
Max Curr Mag Sqrd DIF_a024_maxCurrMagSqrd A2
Rotor Angle DIF_a024_rotorAngle degrees
V Bat DIF_a024_vBat V
Signal Unit
Fail Reason DIF_a024_failReason
0
CACHED
1
POS CURRENT
2
NEG CURRENT
3
DISAGREE
4
TIMEDOUT
5
SWITCH SHORT DISABLE CONDITIONS MET
6
FAULT PRESENT
7
ASC TEST
—
State DIF_a024_state —

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of DIF_a024.