Skip to content

CP_a162 — Pilot Edge Detection Failed CN

Full alert identifier: CP_a162_pilotEdgeDetectionFailedCN

Alert description

The Charge Port (CP) Electronic Control Unit (ECU) is unable to detect the control pilot signal due to an internal condition on the CP ECU. AC charging may be unavailable.

Potential impact

AC charging may not be operational on the next attempt. DC fast charging should remain functional.

Set condition

The CP ECU is unable to receive the expected control pilot signal waveform due to an internal condition on the CP ECU.

Clear condition

Automatically clears when the vehicle is asleep.

Signals to check

Open this alert in Service Mode Plus and review the Payload tab. Use the field names below to identify the values shown by your vehicle.

Signal Unit
Max Pilot Swcan High CP_a162_maxPilotSwcanHigh V
Max Pilot Swcan Low CP_a162_maxPilotSwcanLow V
Min Pilot Swcan High CP_a162_minPilotSwcanHigh V
Min Pilot Swcan Low CP_a162_minPilotSwcanLow V
Signal Unit
Swcan High Mismatch Count CP_a162_swcanHighMismatchCount —
Swcan Low Mismatch Count CP_a162_swcanLowMismatchCount —

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of CP_a162.

Browse all CP alert codes