CP_a151 — Bad Pilot Diode Detected
Full alert identifier: CP_a151_badPilotDiodeDetected
Message shown in the car
Charge port error detected - Service is required AC charging may not function / OK to Supercharge
Alert description
The charge port (CP) electronic control unit (ECU) detects the control pilot voltage is outside of the nominal range while using Tesla electric vehicle supply equipment (EVSE), indicating an internal condition on the CP ECU.
Potential impact
AC charging may be unavailable during the next charging session. No expected impact on Supercharging functionality.
Set condition
The CP ECU detects the control pilot voltage did not go below -10V while using Tesla EVSE.
Clear condition
The CP ECU detects a nominal control pilot voltage or the CP ECU is replaced.
Signals to check
Open this alert in Service Mode Plus and review the Payload tab. Use the field names below to identify the values shown by your vehicle.
| Signal | Unit |
|---|---|
Pilot High Max
CP_
|
V |
Pilot High Min
CP_
|
V |
Pilot Low Max
CP_
|
V |
Pilot Low Min
CP_
|
V |
Check other alerts
With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of CP_a151.