CP_a067 — Gbdc Conn Fault
Full alert identifier: CP_a067_gbdcConnFault
Message shown in the car
Charging equipment reports error Check equipment for error code or message
Alert description
The charge port (CP) electronic control unit (ECU) detects that a GB (Charging standard used in China) DC charger has an issue with the connector.
Potential impact
GB DC charging does not start or is interrupted.
Set condition
The CP ECU receives stop messages from the GB DC charger with the connector faulted bit set.
Clear condition
The CP ECU detects that the GB DC cable is unplugged.
Signals to check
Open this alert in Service Mode Plus and review the Payload tab. Use the field names below to identify the values shown by your vehicle.
| Signal | Unit |
|---|---|
Cc 1 Voltage
CP_
|
V |
Cc 2 Voltage
CP_
|
V |
Check other alerts
With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of CP_a067.