Skip to content

CP_a017 — Five Vov

Full alert identifier: CP_a017_fiveVov

Alert description

The charge port (CP) electronic control unit (ECU) detects an over voltage condition on the internal 5V power supply.

Potential impact

The charge port may not function as expected.

Set condition

The internal 5V power supply voltage measured by the CP ECU is above 5.5V.

Clear condition

The internal 5V power supply voltage measured by the CP ECU is below 5.5V.

Signals to check

Open this alert in Service Mode Plus and review the Payload tab. Use the field names below to identify the values shown by your vehicle.

Signal Unit
5 V Voltage OV CP_a017_5V_VoltageOV V

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of CP_a017.

Browse all CP alert codes