CC_a015 — Pilot A Fault
Full alert identifier: CC_a015_PilotAFault
Message shown in the car
Unable to charge - Vehicle connection issue Insert charge handle fully into charge port
Alert description
Pilot level invalid.
Potential impact
Wall connector will not operate while pilot level is invalid.
Set condition
Pilot level transitions to invalid voltage level.
Clear condition
Pilot level transitions to valid voltage level.
Signals to check
Open this alert in Service Mode Plus and review the Payload tab. Use the field names below to identify the values shown by your vehicle.
| Signal | Unit |
|---|---|
Pilot High Volage
CC_
|
V |
| Signal | Unit |
|---|---|
Sm State
CC_
|
— |
Check other alerts
With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of CC_a015.