CCCM_a007 — Unexpected Force Press
Full alert identifier: CCCM_a007_unexpectedForcePress
Alert description
Center Console Control Module (CCCM) force sensor detects a press without any capacitive press.
Potential impact
Capacitive touch functionality on CCCM may not operate as expected.
Set condition
CCCM detects force sensor detects a press without any capacitive press.
Clear condition
Inspect wiring to CCCM and force sensor and/or re-flash. If error persists after several power cycles, replace CCCM.
Signals to check
These diagnostic fields are associated with CCCM_a007. Check the alert's Payload in Service Mode Plus for available values.
| Signal | Unit |
|---|---|
Drive Button
CCCM_
|
— |
Hazard Button
CCCM_
|
— |
Neutral Button
CCCM_
|
— |
Park Button
CCCM_
|
— |
Reverse Button
CCCM_
|
— |
Check other alerts
With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of CCCM_a007.