CCCM_a002 — Cap Film Outof Range
Full alert identifier: CCCM_a002_capFilmOutofRange
Alert description
Center Console Control Module (CCCM) force sensor film is shorted to ground or Voltage Common Collector (VCC).
Potential impact
Capacitive touch functionality on CCCM may not operate as expected.
Set condition
CCCM detects force sensor film is shorted to ground or VCC.
Clear condition
Inspect wiring to CCCM and capacitive film and/or re-flash. If error persists after several power cycles, replace CCCM.
Signals to check
These diagnostic fields are associated with CCCM_a002. Check the alert's Payload in Service Mode Plus for available values.
| Signal | Unit |
|---|---|
Short To Ground
CCCM_
|
— |
Short To VCC
CCCM_
|
— |
Check other alerts
With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of CCCM_a002.