Skip to content

CCCM_a002 — Cap Film Outof Range

Full alert identifier: CCCM_a002_capFilmOutofRange

Alert description

Center Console Control Module (CCCM) force sensor film is shorted to ground or Voltage Common Collector (VCC).

Potential impact

Capacitive touch functionality on CCCM may not operate as expected.

Set condition

CCCM detects force sensor film is shorted to ground or VCC.

Clear condition

Inspect wiring to CCCM and capacitive film and/or re-flash. If error persists after several power cycles, replace CCCM.

Signals to check

These diagnostic fields are associated with CCCM_a002. Check the alert's Payload in Service Mode Plus for available values.

Signal Unit
Short To Ground CCCM_a002_ShortToGround —
Short To VCC CCCM_a002_ShortToVCC —

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of CCCM_a002.

Browse all CCCM alert codes