BMS_d279 — Fast Charge Pos Contactor A Circuit Failure
Full alert identifier: BMS_d279_fastChargePosContactorACircuitFailure
Alert description
The Battery Management System (BMS) has detected the positive fast charge contactor has fallen open even though it was requested to be closed due to a circuit issue.
Potential impact
Vehicle is unable to charge and may be unable to start or support the low voltage system.
Set condition
The BMS detects there is a circuit issue with the positive fast charge contactor.
Clear condition
This information is not available in the alert reference.
Diagnostic trouble code (DTC)
P0D0701
Fast Charge Positive Contactor A Circuit Failure
Battery Charging System Positive Contactor "A"
Fault type: General Circuit/Electrical Failure
Check other alerts
With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of BMS_d279.