BMS_a109 — HW BMB Mute Status Mismatch
Full alert identifier: BMS_a109_HW_BMB_Mute_Status_Mismatch
Alert description
A battery monitoring board (BMB) device has a mute status that does not align with the mute or unmute command sent by the Battery Management System (BMS).
Potential impact
Bleeding bricks that do not mute during balancing can impact the state of charge (SOC) estimation.
Set condition
Mute is disabled for any device while balancing, or otherwise enabled for any device.
Clear condition
Mute is enabled for all devices while balancing, or otherwise disabled for all devices.
Signals to check
These diagnostic fields are associated with BMS_a109. Check the alert's Payload in Service Mode Plus for available values.
| Signal | Unit |
|---|---|
Mute Mask
BMS_
|
— |
Pack In Bleed
BMS_
|
— |
Check other alerts
With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of BMS_a109.