BMS_a086 — SW FC Contactor Mismatch
Full alert identifier: BMS_a086_SW_FC_Contactor_Mismatch
Alert description
The Battery Management System (BMS) detects a mismatch between actual and commanded fast charge (FC) contactor set state.
Potential impact
DC charging is terminated.
Set condition
High voltage processor (HVP) comms are ok and fast charge contactors were closed and fast charge contactors are now open / opening and BMS_fcContactorRequest has remained closed.
Clear condition
HVP_fcContactorSetState is correct for the current BMS_fcContactorRequest.
Signals to check
These diagnostic fields are associated with BMS_a086. Check the alert's Payload in Service Mode Plus for available values.
| Signal | Unit |
|---|---|
Fc Contactor Set Request
BMS_
|
— |
Fc Contactor Set Request Prev
BMS_
|
— |
Fc Contactor Set State
BMS_
|
— |
Fc Contactor Set State Prev
BMS_
|
— |
Check other alerts
With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of BMS_a086.