BMS_a064 — SW SOC Imbalance
Full alert identifier: BMS_a064_SW_SOC_Imbalance
Alert description
The Battery Management System (BMS) detects a possible state of charge (SOC) imbalance.
Potential impact
Maximum SOC is reduced to 50%.
Set condition
The BMS detects that the difference between the most-charged brick and the least-charge brick in the high voltage (HV) pack is greater than the acceptable threshold.
Clear condition
The BMS has detected that the difference between the maximum brick voltage and the minimum brick voltage is below the acceptable threshold.
Signals to check
Open this alert in Service Mode Plus and review the Payload tab. Use the field names below to identify the values shown by your vehicle.
| Signal | Unit |
|---|---|
Avg Brick SOC
BMS_
|
PCT |
Max Brick SOC
BMS_
|
PCT |
Min Brick SOC
BMS_
|
PCT |
| Signal | Unit |
|---|---|
Max Brick SOCID
BMS_
|
— |
Min Brick SOCID
BMS_
|
— |
Check other alerts
With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of BMS_a064.