Skip to content

BMS_a050 — SW Brick Voltage MIA

Full alert identifier: BMS_a050_SW_Brick_Voltage_MIA

Message shown in the car

Unable to charge Service is required

Alert description

The Battery Management System (BMS) does not have valid data for at least one brick voltage measurement.

Potential impact

Inability to charge, and power is reduced

Set condition

The BMS detects that it does not have valid voltage measurement data for at least one brick.

Clear condition

The Battery Management System (BMS) does have valid data for all brick voltage measurements.

Signals to check

These diagnostic fields are associated with BMS_a050. Check the alert's Payload in Service Mode Plus for available values.

Signal Unit
MIA Brick Id BMS_a050_MIA_brickId —
MIA Num Bad Readings BMS_a050_MIA_numBadReadings —
MIA Num Sna Readings BMS_a050_MIA_numSnaReadings —

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of BMS_a050.

Browse all BMS alert codes