BCFPM_a126 — Motor Overtemperature
Full alert identifier: BCFPM_a126_MotorOvertemperature
Alert description
Prevents doors from operating when door motors exceeds temperature threshold
Potential impact
The power door no longer operates
Set condition
Motor brush temperature exceeds 100 degrees Celsius
Clear condition
Motor brush temperature falls below 80 degrees Celsius
Signals to check
Open this alert in Service Mode Plus and review the Payload tab. Use the field names below to identify the values shown by your vehicle.
| Signal | Unit |
|---|---|
Ambient Temperature
BCFPM_
|
degC |
Door Angle
BCFPM_
|
deg |
Motor Current
BCFPM_
|
A |
Pitch
BCFPM_
|
m/s^2 |
Roll
BCFPM_
|
m/s^2 |
Check other alerts
With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of BCFPM_a126.