BCFPM_a116 — Door Config Error

Full alert identifier: BCFPM_a116_DoorConfigError

Alert description

The door controller's left or right side configuration is invalid or unspecified.

Potential impact

Door controller may not communicate and will not operate as expected. Run the correct 'Side Learn' action to configure it.

Set condition

Door controller side configuration is not set, invalid, or cannot be determined by reading the dedicated harness pins. Alert payload data should provide more information on the specific condition(s) involved.

Clear condition

The door controller's left or right side configuration is valid and correctly set.

Signals to check

These diagnostic fields are associated with BCFPM_a116. Check the alert's Payload in Service Mode Plus for available values.

Signal Unit
Genealogy Invalid Data BCFPM_a116_genealogyInvalidData —
Genealogy Read Error BCFPM_a116_genealogyReadError —
Genlgy Harness Mismatch BCFPM_a116_genlgyHarnessMismatch —
Harness Invalid Data BCFPM_a116_harnessInvalidData —
Harness Read Error BCFPM_a116_harnessReadError —
Side Not Configured BCFPM_a116_sideNotConfigured —

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of BCFPM_a116.