Alert description

The door stopped unexpectedly while opening or closing.

Potential impact

Door opening or closing actuation did not complete.

Set condition

The door controller detected a stopping condition while opening or closing. Alert payload data should provide more information on specific condition(s) involved.

Clear condition

The door exits the release state.

Signals to check

Open this alert in Service Mode Plus and review the Payload tab. Use the field names below to identify the values shown by your vehicle.

Signal Unit
Pitch BCFPM_a083_pitch m/s^2
Roll BCFPM_a083_roll m/s^2
Signal Unit
Door Zeroing Reason BCFPM_a083_doorZeroingReason
0
NONE
1
LATCH CINCHED WITHIN SEAL ZONE
2
MULTIPLE CINCHES AWAY FROM SEAL ZONE
3
ENCODER INVALID LATCH CINCHED
4
CLOSED NO CINCH
—
Release Reason BCFPM_a083_releaseReason —
Unexpected Trip Type BCFPM_a083_unexpectedTripType
0
NONE
1
CURRENT NEGATIVE
2
CURRENT POSITIVE
3
CURRENT ERROR NEGATIVE
4
CURRENT ERROR POSITIVE
5
CURRENT ERROR RATE NEGATIVE
6
CURRENT ERROR RATE POSITIVE
7
COUNT
—

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of BCFPM_a083.