Skip to content

APS_w262 — Vrm Fault Grp B

Full alert identifier: APS_w262_vrmFaultGrpB

Alert description

APS electronic control unit (ECU) encountered a power fault in vrm controller group B (DDR0V75/1V25 rails on 12V architecture, DDR0V75/1V25/CPU on 48V).

Potential impact

Autopilot may be unavailable.

Set condition

Set when a power fault occured in vrm controller group B.

Clear condition

Clear after reboot

Signals to check

These diagnostic fields are associated with APS_w262. Check the alert's Payload in Service Mode Plus for available values.

Signal Unit
Vrm Public Fault Values APS_sw262_vrmPublicFaultValues —
Vrm Rail 1 Fault Values APS_sw262_vrmRail1FaultValues —
Vrm Rail 2 Fault Values APS_sw262_vrmRail2FaultValues —
Vrm Rail 3 Fault Values APS_sw262_vrmRail3FaultValues —
Vrm Type APS_sw262_vrmType
0
TRIP INT VRM
1
CPU GPU VRM
2
DDR 0V75 1V25 VRM
3
TRIP INT GPU VRM
4
DDR 0V75 1V25 CPU VRM
—

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of APS_w262.

Browse all APS alert codes