Skip to content

APS_w188 — Other Turbo Uart MIA

Full alert identifier: APS_w188_otherTurboUartMIA

Alert description

An Autopilot Processor Secondary (APS) device has not received one or more universal asynchronous receiver-transmitter (UART) messages from system-on-chip (SoC) A or B.

Potential impact

AP features will be unavailable.

Set condition

APS (SMS / SMS UART) does not receive one more more UART messages from SoC A or B.

Clear condition

APS (SMS / SMS UART) starts receiving all UART messages from SoC A or B.

Signals to check

These diagnostic fields are associated with APS_w188. Check the alert's Payload in Service Mode Plus for available values.

Signal Unit
Arb Uart Mia State APS_sw188_arbUartMiaState —
Crit Reas Uart Mia State APS_sw188_critReasUartMiaState —
Faults Uart Mia State APS_sw188_faultsUartMiaState —
Other Turbo APS_sw188_otherTurbo
0
A
1
B
2
UNKNOWN
—
Power Uart Mia State APS_sw188_powerUartMiaState —
Reset Uart Mia State APS_sw188_resetUartMiaState —
Sleep Uart Mia State APS_sw188_sleepUartMiaState —
Stat Mon Uart Mia State APS_sw188_statMonUartMiaState —
Show 1 more field
Signal Unit
Wdog State Uart Mia State APS_sw188_wdogStateUartMiaState —

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of APS_w188.

Browse all APS alert codes