Skip to content

ADSP_w069 — Baseamp2 Fault

Full alert identifier: ADSP_w069_baseamp2Fault

Alert description

A electrical fault has been detected in the base amplifier.

Potential impact

Compromised audio performance, signal degradation, or complete loss of audio functionality.

Set condition

A electrical fault has been detected in the base amplifier, possible causes include under-voltage, over-voltage, over-current, over-temperature, clock Phase-Locked Loop issues, or DC offset errors.

Clear condition

The base amplifier electrical fault has been cleared, and normal operation has been restored.

Signals to check

These diagnostic fields are associated with ADSP_w069. Check the alert's Payload in Service Mode Plus for available values.

Signal Unit
Baseamp 2 Fault ADSP_a069_baseamp2Fault
0
NONE
1
OVER TEMP
2
CLOCK PLL
3
OVER CURRENT
4
OVER VOLTAGE
5
UNDER VOLTAGE
6
DC
7
OTHER
—

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of ADSP_w069.

Browse all ADSP alert codes