Universal Mobile Connector alerts
Browse 41 UMC alert codes and open an entry for its description and recorded conditions.
UMC alert codes
Showing 1–41 of 41
- UMC_w001 — Gnd Mon Intrpt Line Side UMC_w001_gndMonIntrptLineSide
- UMC_w002 — GFCI Tripped UMC_w002_GFCITripped
- UMC_w003 — GFCI Self Test Fault UMC_w003_GFCISelfTestFault
- UMC_w004 — Input Over Voltage UMC_w004_inputOverVoltage
- UMC_w005 — Input Under Voltage UMC_w005_inputUnderVoltage
- UMC_w006 — Contactor Welded UMC_w006_contactorWelded
- UMC_w007 — Pcba OT UMC_w007_pcbaOT
- UMC_w008 — Wall Plug OT UMC_w008_wallPlugOT
- UMC_w009 — Veh Conn OT UMC_w009_vehConnOT
- UMC_w010 — Input OT UMC_w010_inputOT
- UMC_w011 — Prox Disconnected UMC_w011_proxDisconnected
- UMC_w012 — Pilot Fault UMC_w012_pilotFault
- UMC_w013 — SA Temperature UMC_w013_SA_Temperature
- UMC_w014 — SA Genealogy UMC_w014_SA_Genealogy
- UMC_w015 — SA Connection UMC_w015_SA_Connection
- UMC_w016 — Pcba OT Foldback UMC_w016_pcbaOTFoldback
- UMC_w017 — Wall Plug OT Foldback UMC_w017_wallPlugOTFoldback
- UMC_w018 — Veh Conn OT Foldback UMC_w018_vehConnOTFoldback
- UMC_w019 — Input OT Foldback UMC_w019_inputOTFoldback
- UMC_w020 — Application CRC UMC_w020_applicationCRC
- UMC_w021 — Data Bus UMC_w021_dataBus
- UMC_w022 — Critical RAM UMC_w022_criticalRAM
- UMC_w023 — Adc Self Test UMC_w023_adcSelfTest
- UMC_w024 — Gnd Resistance High UMC_w024_gndResistanceHigh The Universal Mobile Connector (UMC) detects a European Smart Adapter is connected, and the UMC also senses a high impedance ground connection.
- UMC_w025 — Cntr Open Expected Close UMC_w025_cntrOpenExpectedClose
- UMC_w026 — V Ref Out Of Range UMC_w026_vRefOutOfRange
- UMC_w027 — Watchdog Expired UMC_w027_watchdogExpired
- UMC_w028 — Processor Booted UMC_w028_processorBooted
- UMC_w029 — Ac Power Loss UMC_w029_acPowerLoss
- UMC_w030 — Ac Lost Pll Lock UMC_w030_acLostPllLock
- UMC_w031 — Relay Coil V Irrational UMC_w031_relayCoilVIrrational
- UMC_w032 — Chc Vitals Request Failure UMC_w032_chcVitalsRequestFailure
- UMC_w033 — Chc Update Fault UMC_w033_chcUpdateFault
- UMC_w034 — V2l SA Unsupported UMC_w034_v2lSAUnsupported
- UMC_w035 — V2l HVAC Detected UMC_w035_v2lHVACDetected
- UMC_w036 — SA gpio UMC_w036_SA_gpio
- UMC_w037 — GFCI Calibration UMC_w037_GFCICalibration
- UMC_w038 — Chc Vitals Fault UMC_w038_chcVitalsFault
- UMC_w039 — Input Over Current UMC_w039_inputOverCurrent
- UMC_w040 — Gnd Disconnected UMC_w040_gndDisconnected Universal Mobile Connector (UMC) AC input side ground impedance exceeded warning threshold. Charging is not affected.
- UMC_w041 — Handle Temp Irrational UMC_w041_handleTempIrrational