Power-line communication relay alerts
Browse 52 PLCRLY alert codes and open an entry for its description and recorded conditions.
PLCRLY alert codes
Showing 1–50 of 52
- PLCRLY_a001 — Can Rx PLCRLY_a001_canRx
- PLCRLY_a002 — Can Tx PLCRLY_a002_canTx
- PLCRLY_a003 — Can Error PLCRLY_a003_canError
- PLCRLY_a004 — Proximity Rationality PLCRLY_a004_proximityRationality The Power Line Communication Relay (PLCRLY) electronic control unit (ECU) detects proximity voltage in an unexpected range.
- PLCRLY_a006 — Lost Comms BMS PLCRLY_a006_lostCommsBMS
- PLCRLY_a007 — Watchdog PLCRLY_a007_watchdog
- PLCRLY_a008 — Memory Error PLCRLY_a008_memoryError The Power Line Communication Relay (PLCRLY) electronic control unit (ECU) detects a memory error.
- PLCRLY_a010 — Pilot Rationality PLCRLY_a010_pilotRationality The Power Line Communication Relay (PLCRLY) electronic control unit (ECU) receives pilot sensor readings that are outside of the expected range.
- PLCRLY_a013 — Lost Comms GTW PLCRLY_a013_lostCommsGTW
- PLCRLY_a014 — Lost Comms CHG PLCRLY_a014_lostCommsCHG
- PLCRLY_a026 — Network Management PLCRLY_a026_networkManagement
- PLCRLY_a046 — Lost Comms EVSE PLCRLY_a046_lostCommsEVSE Vehicle unexpectedly lost digital communications with offboard charging equipment. Charging may be interrupted.
- PLCRLY_a052 — Evse Not Supported PLCRLY_a052_evseNotSupported
- PLCRLY_a053 — Prox Latched No Pilot PLCRLY_a053_proxLatchedNoPilot
- PLCRLY_a055 — Charge Stopped No Pilot PLCRLY_a055_chargeStoppedNoPilot
- PLCRLY_a056 — Prox Disconnected PLCRLY_a056_proxDisconnected
- PLCRLY_a057 — Ccs1 Adapter Btn Press PLCRLY_a057_ccs1AdapterBtnPress The Power-Line Communication (PLC) relay detected that button was pressed on the charge cable connected to the Combined Charging System (CCS) Combo 1 Adapter.
- PLCRLY_a062 — Sc Out Of Service PLCRLY_a062_scOutOfService
- PLCRLY_a063 — Sc Update In Progress PLCRLY_a063_scUpdateInProgress
- PLCRLY_a064 — Supercharging Blocked PLCRLY_a064_superchargingBlocked
- PLCRLY_a065 — Self Test Failed PLCRLY_a065_selfTestFailed
- PLCRLY_a066 — Prox Latched Idle Pilot PLCRLY_a066_proxLatchedIdlePilot
- PLCRLY_a071 — Exi Decode Failure PLCRLY_a071_exiDecodeFailure The Power Line Communication Relay (PLCRLY) electronic control unit (ECU) is unable to read the received Combined Charging System (CCS) vehicle to grid (V2G) messages.
- PLCRLY_a072 — V2g Evcc Timeout PLCRLY_a072_v2gEvccTimeout The Power Line Communication Relay (PLCRLY) electronic control unit (ECU) detects that the charging session is taking longer to startup than expected and exceeds the maximum time frame.
- PLCRLY_a073 — Iec Combo Shutdown PLCRLY_a073_iecComboShutdown The Power Line Communication Relay (PLCRLY) electronic control unit (ECU) detects the Combined Charging System (CCS) charge session has ended.
- PLCRLY_a074 — Failed To Est V2g Comm PLCRLY_a074_failedToEstV2gComm The Power Line Communication Relay (PLCRLY) electronic control unit (ECU) is unable to communicate with the electric vehicle supply equipment (EVSE).
- PLCRLY_a075 — V2g Comms Failure PLCRLY_a075_v2gCommsFailure The Power Line Communication Relay (PLCRLY) electronic control unit (ECU) does not receive the expected Combined Charging System (CCS) vehicle to grid (V2G) messages within the expected time frame.
- PLCRLY_a077 — Invalid Mac Address PLCRLY_a077_invalidMacAddress
- PLCRLY_a089 — Plc Config Mismatch PLCRLY_a089_plcConfigMismatch
- PLCRLY_a090 — Ccs Evse Low Iso PLCRLY_a090_ccsEvseLowIso
- PLCRLY_a092 — Modem App Load Failed PLCRLY_a092_modemAppLoadFailed The Power Line Communication (PLC) modem application does not load after maximum number of automatic retries. DC fast charging will be unavailable at Combined Charging System (CCS) charge stations.
- PLCRLY_a093 — Modem Loaded With Reset PLCRLY_a093_modemLoadedWithReset The Power Line Communication (PLC) modem successfully booted its application but first required the Power Line Communication Relay (PLCRLY) electronic control unit (ECU) to reset.
- PLCRLY_a095 — Thermal Dc Limit Active PLCRLY_a095_thermalDcLimitActive
- PLCRLY_a114 — Ccs Evse Failed PLCRLY_a114_ccsEvseFailed The Combined Charging System (CCS) charge station reports that it has experienced a failure. Charging may not start or may be interrupted, with a charge cable cycle (disconnect, then reconnect to vehicle) required before charging can start…
- PLCRLY_a118 — Iec Combo Lock Up PLCRLY_a118_iecComboLockUp Charge port detected a CCS lockup
- PLCRLY_a119 — Plc Transmit Failure PLCRLY_a119_plcTransmitFailure Charge port detected PLC transmission failure
- PLCRLY_a120 — Combo Adapter Foldback PLCRLY_a120_comboAdapterFoldback The Power-Line Communication (PLC) relay detected that the Combined Charging System (CCS) Combo 1 Adapter temperature is higher than expected. The charging rate may be reduced.
- PLCRLY_a121 — Lost Comms CP PLCRLY_a121_lostCommsCP ONLY USED BY PLCRLY. Indicates lack of communication with CP component.
- PLCRLY_a122 — Plc Modem Failure PLCRLY_a122_plcModemFailure Charge port detected an error with PLC modem
- PLCRLY_a131 — Evse Comm Timeout PLCRLY_a131_evseCommTimeout Indicates that communication between the EVSE and the CP timed out
- PLCRLY_a132 — Contract Auth Timeout PLCRLY_a132_contractAuthTimeout Charging session cannot begin because the EVSE is still in authentication state
- PLCRLY_a133 — Prox Never Latched PLCRLY_a133_proxNeverLatched Cable proximity did not latch within the expected timeframe
- PLCRLY_a135 — Sdp Attempts Failed PLCRLY_a135_sdpAttemptsFailed Charging session not started due to communication failures during the EVSE discovery protocol (SDP) which occurs during CCS charging
- PLCRLY_a136 — Sc Sdp Comms Failure PLCRLY_a136_scSdpCommsFailure Failed to establish comms with supercharger during SECC discovery
- PLCRLY_a136 — Sdp Side Req Failed PLCRLY_a136_sdpSideReqFailed Failed to receive a proper SDP response for a required TCP port from the EVSE
- PLCRLY_a137 — Plc Forward Error PLCRLY_a137_plcForwardError PlcForward module detected an error has occured
- PLCRLY_a139 — Pilot Faulted PLCRLY_a139_pilotFaulted An EVSE using legacy pilot has faulted
- PLCRLY_a145 — Modem App Load Failed NA PLCRLY_a145_modemAppLoadFailedNA The Power Line Communication (PLC) modem application does not load after a maximum number of automatic retries. DC fast charging will be unavailable at Combined Charging System (CCS) charge stations.
- PLCRLY_a146 — Ccs Evse Malfunction PLCRLY_a146_ccsEvseMalfunction The Combined Charging System (CCS) charge station reports that it has experienced an unrecoverable error. Charging may not start or may be interrupted, with a charge cable cycle (disconnect, then reconnect to vehicle) required before charg…
- PLCRLY_a149 — Pilot Period Invalid PLCRLY_a149_pilotPeriodInvalid The Power-Line Communication (PLC) relay has detected a pilot signal with an invalid period