Showing 1–39 of 39
- CC_f001 — Gnd Mon Intrpt Line Side CC_f001_gndMonIntrptLineSide Wall connector protective earth is disconnected or grounding scheme dual in-line package (DIP) switch is set incorrectly.
- CC_f002 — Gnd Mon Intrpt Load Side CC_f002_gndMonIntrptLoadSide Vehicle-side protective earth is disconnected from wall connector.
- CC_f003 — CCID Tripped CC_f003_CCIDTripped Ground fault current exceeded threshold.
- CC_f004 — CCID Self Test Fault CC_f004_CCIDSelfTestFault Ground fault detection circuit self-test failed.
- CC_f005 — Grounded Neutral CC_f005_groundedNeutral Neutral conductor is grounded on vehicle side.
- CC_f006 — Input Over Current CC_f006_inputOverCurrent Contactors opened due to measured current exceeding configured unit current limit or sharing network allocated current.
- CC_f007 — Input Over Voltage CC_f007_inputOverVoltage Alternating current (AC) root mean square (RMS) input voltage is too high.
- CC_f008 — Input Under Voltage CC_f008_inputUnderVoltage Alternating current (AC) root mean square (RMS) input voltage is too low.
- CC_f009 — Input Miswired CC_f009_inputMiswired Wall connector input wiring connections are incorrect.
- CC_f010 — Contactor Welded CC_f010_contactorWelded Contactor detected as closed when it should be open.
- CC_f011 — Ambient OT CC_f011_ambientOT Wall connector printed circuit board assembly (PCBA) temperature is too high.
- CC_f012 — Wall Plug OT CC_f012_wallPlugOT Wall connector input wiring temperature is too high.
- CC_f013 — Veh Conn OT CC_f013_vehConnOT Wall connector charge handle temperature too high.
- CC_f014 — Mcu Self Test Fault CC_f014_mcuSelfTestFault Wall connector microcontroller internal self-test fault.
- CC_f015 — Pilot A Fault CC_f015_PilotAFault Pilot level invalid.
- CC_f016 — Pilot B Fault CC_f016_PilotBFault Pilot level invalid.
- CC_f017 — Pilot C Fault CC_f017_PilotCFault Pilot level invalid.
- CC_f018 — Pilot D Fault CC_f018_PilotDFault Pilot level invalid.
- CC_f019 — Prox Disconnected CC_f019_proxDisconnected Wall connector proximity line disconnected or vehicle is not providing proximity voltage.
- CC_f020 — 3v Rail Incorrect CC_f020_3vRailIncorrect Microcontroller supply rail is incorrect.
- CC_f021 — CB no Master CC_f021_CB_noMaster Wall connector is configured as a slave, but no master was detected.
- CC_f022 — CB too Many Masters CC_f022_CB_tooManyMasters More than 1 wall connector is configured as a master on the sharing network.
- CC_f023 — CB too Many Slaves CC_f023_CB_tooManySlaves More than 3 units configured as slaves were detected on the sharing network.
- CC_f024 — CB master I Set Too Low CC_f024_CB_masterISetTooLow Master unit current limit set too low.
- CC_f025 — Evse Temp CC_f025_evseTemp Wall connector printed circuit board assembly (PCBA) temperature sensor shorted, open, or too cold.
- CC_f026 — Wall Plug Temp CC_f026_wallPlugTemp Wall connector input terminal temperature sensor shorted, open, or too cold.
- CC_f027 — Vehicle Handle Temp CC_f027_vehicleHandleTemp Wall connector charge handle temperature sensor shorted, open, or too cold.
- CC_f028 — CB rotary Select CC_f028_CB_rotarySelect Invalid rotary dial selection.
- CC_f029 — Pilot F Fault CC_f029_PilotFFault Pilot level invalid.
- CC_f030 — Master Slave Mismatch CC_f030_masterSlaveMismatch Master and slave units in the sharing network have different nameplate current ratings.
- CC_f031 — Pll Lock Lost CC_f031_pllLockLost Alternating current (AC) line phase-locked loop (PLL) failed to lock. Check grid frequency and quality.
- CC_f032 — Metering Failure CC_f032_meteringFailure Output voltage, current, and energy monitoring failure.
- CC_f033 — V Ref Out Of Range CC_f033_vRefOutOfRange Wall connector internal voltage reference is out of acceptable range.
- CC_f036 — Contactor Stuck Open CC_f036_contactorStuckOpen Wall connector contactor output shows no voltage when expected to be closed on one or more phases.
- CC_f037 — Int Module Wdt Expired CC_f037_intModuleWdtExpired Wall connector internal watchdog timer expired and the unit is about to reboot.
- CC_f038 — Internal Module Mia CC_f038_internalModuleMia Wall connector Wi-Fi module hasn't checked in with the real-time processor.
- CC_f039 — Internal Module Over Temp CC_f039_internalModuleOverTemp Wall connector real-time processor is too hot.
- CC_f040 — Handle Temp Foldback CC_f040_handleTempFoldback Wall connector charge handle is too hot.
- CC_f041 — Input Wiring Foldback CC_f041_inputWiringFoldback Input wiring terminals are too hot as detected by non-contact infrared (IR) sensor.