CP_w201 — Uhf Door Open Over Limit

Full alert identifier: CP_w201_uhfDoorOpenOverLimit

Alert description

The Charge Port (CP) Electronic Control Unit (ECU) detects excessive ultra-high frequency (UHF) requests from a nearby charge cable.

Potential impact

Charge port door may not open in response to UHF request until the next drive or charge cycle.

Set condition

Charge port door is repeatedly opened from UHF requests without any charge cable being inserted.

Clear condition

A new drive or charging cycle is started.

Signals to check

These diagnostic fields are associated with CP_w201. Check the alert's Payload in Service Mode Plus for available values.

Signal Unit
Uhf Door Request Counts CP_a201_uhfDoorRequestCounts —

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of CP_w201.