BMS_w180 — Replace Smart Fuse Block Hv
Full alert identifier: BMS_w180_ReplaceSmartFuseBlockHv
Message shown in the car
Battery fuse replacement required Schedule service immediately
Alert description
The Battery Management System (BMS) has detected the High Voltage (HV) battery pyro fuse is close to expiration or expired. The fuse must be replaced with a new self-powered hybrid pyro fuse.
Potential impact
The pack contactors are blocked from closing and the vehicle is unable to drive.
Set condition
BMS detects that the HV battery pyro fuse is 15 months past its recommended end of life.
Clear condition
Pyro fuse is replaced with a self-powered hybrid pyro fuse.
Signals to check
Open this alert in Service Mode Plus and review the Payload tab. Use the field names below to identify the values shown by your vehicle.
| Signal | Unit |
|---|---|
Fuse Age
BMS_
|
Years |
| Signal | Unit |
|---|---|
Fuse Born Month
BMS_
|
— |
Fuse Born Year
BMS_
|
— |
Fuse Type
BMS_
|
— |
Check other alerts
With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of BMS_w180.