- RCM2_a393 — Side Accel B Pil LC Los Coup RCM2_a393_sideAccelBPilLCLosCoup The b-pillar left impact sensor has a cross coupling condition.
- RCM2_a394 — Side Accel B Pil L Comm Err RCM2_a394_sideAccelBPilLCommErr The b-pillar left impact sensor has a communication condition.
- RCM2_a395 — Side Accel B Pil L Init Typ RCM2_a395_sideAccelBPilLInitTyp The b-pillar left impact sensor has an initialization failure.
- RCM2_a396 — Side Accel B Pil L Config RCM2_a396_sideAccelBPilLConfig The b-pillar left impact sensor is not configured but is physically present.
- RCM2_a397 — Side Accel B Pil L Defect RCM2_a397_sideAccelBPilLDefect The b-pillar left impact sensor has a defect.
- RCM2_a398 — Side Accel B Pil L Sig Mon RCM2_a398_sideAccelBPilLSigMon The b-pillar left impact sensor has a signal monitoring condition.
- RCM2_a400 — Side Accel B Pil R Sht2 Gnd RCM2_a400_sideAccelBPilRSht2Gnd The b-pillar right impact sensor has a short to ground.
- RCM2_a401 — Side Accel B Pil R Sht2 Bat RCM2_a401_sideAccelBPilRSht2Bat The b-pillar right impact sensor has a short to battery.
- RCM2_a402 — Side Accel B Pil R Open RCM2_a402_sideAccelBPilROpen The b-pillar right impact sensor has an open circuit.
- RCM2_a403 — Side Accel B Pil R Crss Coup RCM2_a403_sideAccelBPilRCrssCoup The b-pillar right impact sensor has a cross coupling condition.
- RCM2_a404 — Side Accel B Pil R Comm Err RCM2_a404_sideAccelBPilRCommErr The b-pillar right impact sensor has a communication condition.
- RCM2_a405 — Side Accel B Pil R Init Typ RCM2_a405_sideAccelBPilRInitTyp The b-pillar right impact sensor has an initialization failure.
- RCM2_a406 — Side Accel B Pil R Config RCM2_a406_sideAccelBPilRConfig The b-pillar right impact sensor is not configured but is physically present.
- RCM2_a407 — Side Accel B Pil R Defect RCM2_a407_sideAccelBPilRDefect The b-pillar right impact sensor has a defect.
- RCM2_a408 — Side Accel B Pil R Sig Mon RCM2_a408_sideAccelBPilRSigMon The b-pillar right impact sensor has a signal monitoring condition.
- RCM2_a410 — Side Accel C Pil L Sht2 Gnd RCM2_a410_sideAccelCPilLSht2Gnd The c-pillar left impact sensor has a short to ground.
- RCM2_a411 — Side Accel C Pil L Sht2 Bat RCM2_a411_sideAccelCPilLSht2Bat The c-pillar left impact sensor has a short to battery.
- RCM2_a412 — Side Accel C Pil L Open RCM2_a412_sideAccelCPilLOpen The c-pillar left impact sensor has an open circuit.
- RCM2_a413 — Side Accel C Pil L Crss Coup RCM2_a413_sideAccelCPilLCrssCoup The c-pillar left impact sensor has a cross coupling condition.
- RCM2_a414 — Side Accel C Pil L Comm Err RCM2_a414_sideAccelCPilLCommErr The c-pillar left impact sensor has a communication condition.
- RCM2_a415 — Side Accel C Pil L Init Typ RCM2_a415_sideAccelCPilLInitTyp The c-pillar left impact sensor has an initialization failure.
- RCM2_a416 — Side Accel C Pil L Config RCM2_a416_sideAccelCPilLConfig The c-pillar left impact sensor is not configured but is physically present.
- RCM2_a417 — Side Accel C Pil L Defect RCM2_a417_sideAccelCPilLDefect The c-pillar left impact sensor has a defect.
- RCM2_a418 — Side Accel C Pil L Sig Mon RCM2_a418_sideAccelCPilLSigMon The c-pillar left impact sensor has a signal monitoring condition.
- RCM2_a420 — Side Accel C Pil R Sht2 Gnd RCM2_a420_sideAccelCPilRSht2Gnd The c-pillar right impact sensor has a short to ground.
- RCM2_a421 — Side Accel C Pil R Sht2 Bat RCM2_a421_sideAccelCPilRSht2Bat The c-pillar right impact sensor has a short to battery.
- RCM2_a422 — Side Accel C Pil R Open RCM2_a422_sideAccelCPilROpen The c-pillar right impact sensor has an open circuit.
- RCM2_a423 — Side Accel C Pil R Crss Coup RCM2_a423_sideAccelCPilRCrssCoup The c-pillar right impact sensor has a cross coupling condition.
- RCM2_a424 — Side Accel C Pil R Comm Err RCM2_a424_sideAccelCPilRCommErr The c-pillar right impact sensor has a communication condition.
- RCM2_a425 — Side Accel C Pil R Init Typ RCM2_a425_sideAccelCPilRInitTyp The c-pillar right impact sensor has an initialization failure.
- RCM2_a426 — Side Accel C Pil R Config RCM2_a426_sideAccelCPilRConfig The c-pillar right impact sensor is not configured but is physically present.
- RCM2_a427 — Side Accel C Pil R Defect RCM2_a427_sideAccelCPilRDefect The c-pillar right impact sensor has a defect.
- RCM2_a428 — Side Accel C Pil R Sig Mon RCM2_a428_sideAccelCPilRSigMon The c-pillar right impact sensor has a signal monitoring condition.
- RCM2_a430 — Pres Frnt L Door Sht2 Gnd RCM2_a430_presFrntLDoorSht2Gnd The front left door pressure impact sensor has a short to ground.
- RCM2_a431 — Pres Frnt L Door Sht2 Bat RCM2_a431_presFrntLDoorSht2Bat The front left door pressure impact sensor has a short to battery.
- RCM2_a432 — Pres Frnt L Door Open RCM2_a432_presFrntLDoorOpen The front left door pressure impact sensor has an open circuit.
- RCM2_a433 — Pres Frnt L Door Crss Coup RCM2_a433_presFrntLDoorCrssCoup The front left door pressure impact sensor has a cross coupling condition.
- RCM2_a434 — Pres Frnt L Door Comm Err RCM2_a434_presFrntLDoorCommErr The front left door pressure impact sensor has a communication condition.
- RCM2_a435 — Pres Frnt L Door Init Typ RCM2_a435_presFrntLDoorInitTyp The front left door pressure impact sensor has an initialization failure.
- RCM2_a436 — Pres Frnt L Door Config RCM2_a436_presFrntLDoorConfig The front left door pressure impact sensor is not configured but is physically present.
- RCM2_a437 — Pres Frnt L Door Defect RCM2_a437_presFrntLDoorDefect The front left door pressure impact sensor has a defect.
- RCM2_a438 — Pres Frnt L Door Sig Mon RCM2_a438_presFrntLDoorSigMon The front left door pressure impact sensor has a signal monitoring condition.
- RCM2_a439 — Pres Door Absolute1 RCM2_a439_presDoorAbsolute1 The door pressure impact sensor has absolute pressure failure 1.
- RCM2_a440 — Pres Frnt R Door Sht2 Gnd RCM2_a440_presFrntRDoorSht2Gnd The front right door pressure impact sensor has a short to ground.
- RCM2_a441 — Pres Frnt R Door Sht2 Bat RCM2_a441_presFrntRDoorSht2Bat The front right door pressure impact sensor has a short to battery.
- RCM2_a442 — Pres Frnt R Door Open RCM2_a442_presFrntRDoorOpen The front right door pressure impact sensor has an open circuit.
- RCM2_a443 — Pres Frnt R Door Crss Coup RCM2_a443_presFrntRDoorCrssCoup The front right door pressure impact sensor has a cross coupling condition.
- RCM2_a444 — Pres Frnt R Door Comm Err RCM2_a444_presFrntRDoorCommErr The front right door pressure impact sensor has a communication condition.
- RCM2_a445 — Pres Frnt R Door Init Typ RCM2_a445_presFrntRDoorInitTyp The front right door pressure impact sensor has an initialization failure.
- RCM2_a446 — Pres Frnt R Door Config RCM2_a446_presFrntRDoorConfig The front right door pressure impact sensor is not configured but is physically present.