- RCM2_a179 — Cur AB2nd Row R Short RCM2_a179_curAB2ndRowRShort The 2nd row right curtain airbag has a resistance that is too low.
- RCM2_a180 — Cur AB2nd Row R Crss Coup RCM2_a180_curAB2ndRowRCrssCoup The 2nd row right curtain airbag has a cross coupling condition.
- RCM2_a181 — Cur AB2nd Row R Config RCM2_a181_curAB2ndRowRConfig The 2nd row right curtain airbag is not configured in firmware but is physically present.
- RCM2_a182 — Hood Actuator R Sht2 Gnd RCM2_a182_hoodActuatorRSht2Gnd The right pedestrian protection hood actuator has a short to ground.
- RCM2_a183 — Hood Actuator R Sht2 Bat RCM2_a183_hoodActuatorRSht2Bat The right pedestrian protection hood actuator has a short to battery.
- RCM2_a184 — Hood Actuator R Open RCM2_a184_hoodActuatorROpen The right pedestrian protection hood actuator has a resistance that is too high.
- RCM2_a185 — Hood Actuator R Short RCM2_a185_hoodActuatorRShort The right pedestrian protection hood actuator has a resistance that is too low.
- RCM2_a186 — Hood Actuator R Crss Coup RCM2_a186_hoodActuatorRCrssCoup The right pedestrian protection hood actuator has a cross coupling condition.
- RCM2_a187 — Hood Actuator R Config RCM2_a187_hoodActuatorRConfig The right pedestrian protection hood actuator is not configured in firmware but is physically present.
- RCM2_a188 — Hood Actuator L Sht2 Gnd RCM2_a188_hoodActuatorLSht2Gnd The left pedestrian protection hood actuator has a short to ground.
- RCM2_a189 — Hood Actuator L Sht2 Bat RCM2_a189_hoodActuatorLSht2Bat The left pedestrian protection hood actuator has a short to battery.
- RCM2_a190 — Hood Actuator L Open RCM2_a190_hoodActuatorLOpen The left pedestrian protection hood actuator has a resistance that is too high.
- RCM2_a191 — Hood Actuator L Short RCM2_a191_hoodActuatorLShort The left pedestrian protection hood actuator has a resistance that is too low.
- RCM2_a192 — Hood Actuator L Crss Coup RCM2_a192_hoodActuatorLCrssCoup The left pedestrian protection hood actuator has a cross coupling condition.
- RCM2_a193 — Hood Actuator L Config RCM2_a193_hoodActuatorLConfig The left pedestrian protection hood actuator is not configured in firmware but is physically present.
- RCM2_a194 — Driver ABAV Sht2 Gnd RCM2_a194_driverABAVSht2Gnd The driver active vent has a short to ground.
- RCM2_a195 — Driver ABAV Sht2 Bat RCM2_a195_driverABAVSht2Bat The driver active vent has a short to battery.
- RCM2_a196 — Driver ABAV Open RCM2_a196_driverABAVOpen The driver active vent has an open circuit.
- RCM2_a197 — Driver ABAV Short RCM2_a197_driverABAVShort The driver active vent has a resistance that is too low.
- RCM2_a198 — Driver ABAV Cross Coup RCM2_a198_driverABAVCrossCoup The driver active vent has a cross coupling condition.
- RCM2_a199 — Driver ABAV Config RCM2_a199_driverABAVConfig The driver active vent is not configured in firmware but is physically present.
- RCM2_a200 — Driver FSAB Sht2 Gnd RCM2_a200_driverFSABSht2Gnd The inboard driver seat (Farside) airbag has a short to ground.
- RCM2_a201 — Driver FSAB Sht2 Bat RCM2_a201_driverFSABSht2Bat The inboard driver seat (Farside) airbag has a short to battery.
- RCM2_a202 — Driver FSAB Open RCM2_a202_driverFSABOpen The Restraint Control Module (RCM) detects an open circuit on the farside airbag (FSAB), which is the inboard airbag located in the driver's seat.
- RCM2_a203 — Driver FSAB Short RCM2_a203_driverFSABShort The inboard driver seat (Farside) airbag has a resistance that is too low.
- RCM2_a204 — Driver FSAB Cross Coup RCM2_a204_driverFSABCrossCoup The inboard driver seat (Farside) airbag has a cross coupling condition.
- RCM2_a205 — Driver FSAB Config RCM2_a205_driverFSABConfig The inboard driver seat (Farside) airbag is not configured in firmware but is physically present.
- RCM2_a206 — Side AB2nd Row L Sht2 Gnd RCM2_a206_sideAB2ndRowLSht2Gnd The 2nd row left side airbag has a short to ground.
- RCM2_a207 — Side AB2nd Row L Sht2 Bat RCM2_a207_sideAB2ndRowLSht2Bat The 2nd row left side airbag has a short to battery.
- RCM2_a208 — Side AB2nd Row L Open RCM2_a208_sideAB2ndRowLOpen The 2nd row left side airbag has an open circuit.
- RCM2_a209 — Side AB2nd Row L Short RCM2_a209_sideAB2ndRowLShort The 2nd row left side airbag has a resistance that is too low.
- RCM2_a210 — Side AB2nd Row L Crss Coup RCM2_a210_sideAB2ndRowLCrssCoup The 2nd row left side airbag has a cross coupling condition.
- RCM2_a211 — Side AB2nd Row L Config RCM2_a211_sideAB2ndRowLConfig The 2nd row left side airbag is not configured in firmware but is physically present.
- RCM2_a212 — Side AB2nd Row R Sht2 Gnd RCM2_a212_sideAB2ndRowRSht2Gnd The 2nd row right side airbag has a short to ground.
- RCM2_a213 — Side AB2nd Row R Sht2 Bat RCM2_a213_sideAB2ndRowRSht2Bat The 2nd row right side airbag has a short to battery.
- RCM2_a214 — Side AB2nd Row R Open RCM2_a214_sideAB2ndRowROpen The 2nd row right side airbag has an open circuit.
- RCM2_a215 — Side AB2nd Row R Short RCM2_a215_sideAB2ndRowRShort The 2nd row right side airbag has a resistance that is too low.
- RCM2_a216 — Side AB2nd Row R Crss Coup RCM2_a216_sideAB2ndRowRCrssCoup The 2nd row right side airbag has a cross coupling condition.
- RCM2_a217 — Side AB2nd Row R Config RCM2_a217_sideAB2ndRowRConfig The 2nd row right side airbag is not configured in firmware but is physically present.
- RCM2_a250 — Ens1 Sht2 Bat RCM2_a250_ens1Sht2Bat The emergency notification signal connected to the High Voltage Contactor has a short to battery.
- RCM2_a251 — Ens1 Sht2 Gnd RCM2_a251_ens1Sht2Gnd The emergency notification signal connected to the High Voltage Contactor has a short to ground or is open.
- RCM2_a252 — Ens1 Config RCM2_a252_ens1Config The emergency notification signal connected to the High Voltage Contactor is not configured but is physically present.
- RCM2_a253 — Ens2 Sht2 Bat RCM2_a253_ens2Sht2Bat The emergency notification signal connected to ecall has a short to battery.
- RCM2_a254 — Ens2 Sht2 Gnd RCM2_a254_ens2Sht2Gnd The Emergency Notification Signal Connected to eCall has no power source or is shorted to ground.
- RCM2_a255 — Ens2 Config RCM2_a255_ens2Config The emergency notification signal connected to ecall is not configured but is physically present.
- RCM2_a256 — Ens3 Sht2 Bat RCM2_a256_ens3Sht2Bat The ens3 has a short to battery.
- RCM2_a257 — Ens3 Sht2 Gnd RCM2_a257_ens3Sht2Gnd The ens3 has a short to ground.
- RCM2_a258 — Ens3 Config RCM2_a258_ens3Config The ens3 is not configured but is physically present.
- RCM2_a259 — Ens4 Sht2 Bat RCM2_a259_ens4Sht2Bat The ens4 has a short to battery.
- RCM2_a260 — Ens4 Sht2 Gnd RCM2_a260_ens4Sht2Gnd The ens4 has a short to ground.