Skip to content

VCRIGHT_a596 — Front Door Latch Unexpected Voltage

Full alert identifier: VCRIGHT_a596_frontDoorLatchUnexpectedVoltage

Alert description

The front door latch ajar switch voltage is outside the expected ranges.

Potential impact

The front door may not operate as expected.

Set condition

The reported switch voltage is outside of the range 0.39 V to 0.55 V and 4.18 V to 4.70 V.

Clear condition

The reported switch voltage is between 0.39 V to 0.55 V or 4.18 V to 4.70 V.

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of VCRIGHT_a596.

Browse all VCRIGHT alert codes