VCRIGHT_a577 — Bsi Hardware Issue
Full alert identifier: VCRIGHT_a577_bsiHardwareIssue
Alert description
A condition affecting the blind spot indicator light has been detected. The indicator light may be unavailable or may not function as expected.
Potential impact
The blind spot indicator light may be unavailable or may not function as expected.
Set condition
The blind spot indicator light is disconnected, shorted to GND, voltage feedback when illuminated is not within the expected threshold, or the eFuse is tripped.
Clear condition
The blind spot indicator light is connected, voltage feedback when illuminated is within 2V - 4V, and the eFuse is not tripped.
Check other alerts
With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of VCRIGHT_a577.