Skip to content

VCLEFT_a494 — 12v Socket Rear eFuse Trip

Full alert identifier: VCLEFT_a494_12vSocketRearEFuseTrip

Alert description

The Left Vehicle Controller (VCLEFT) detects an eFuse overcurrent event (or a trip) on the rear 12V socket power feed.

Potential impact

The rear 12V socket may not function as expected.

Set condition

The VCLEFT detects an eFuse overcurrent event on the rear 12V socket power feed.

Clear condition

The VCLEFT no longer detects an eFuse overcurrent event on the rear 12V socket power feed after one of the following: a complete sleep cycle, reset, or a successful attempt to repower the circuit.

Signals to check

Open this alert in Service Mode Plus and review the Payload tab. Use the field names below to identify the values shown by your vehicle.

Signal Unit
12 V Socket Rear E Fuse Current VCLEFT_a494_12vSocketRearEFuseCurrent
511
SNA
A

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of VCLEFT_a494.

Browse all VCLEFT alert codes