VCLEFT_a494 — 12v Socket Rear eFuse Trip
Full alert identifier: VCLEFT_a494_12vSocketRearEFuseTrip
Alert description
The Left Vehicle Controller (VCLEFT) detects an eFuse overcurrent event (or a trip) on the rear 12V socket power feed.
Potential impact
The rear 12V socket may not function as expected.
Set condition
The VCLEFT detects an eFuse overcurrent event on the rear 12V socket power feed.
Clear condition
The VCLEFT no longer detects an eFuse overcurrent event on the rear 12V socket power feed after one of the following: a complete sleep cycle, reset, or a successful attempt to repower the circuit.
Signals to check
Open this alert in Service Mode Plus and review the Payload tab. Use the field names below to identify the values shown by your vehicle.
| Signal | Unit |
|---|---|
12 V Socket Rear E Fuse Current
VCLEFT_
|
A |
Check other alerts
With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of VCLEFT_a494.