VCLEFT_a413 — Undervoltage Self Test Failure
Full alert identifier: VCLEFT_a413_undervoltageSelfTestFailure
Alert description
The Battery Domain Left Controller Undervoltage self-test did not pass. A condition affecting a load on the Battery Domain was detected during the self-test.
Potential impact
The undervoltage protection circuit may not function as expected.
Set condition
The Battery Domain Left Controller Undervoltage self-test does not pass. If a stuck-on or stuck-off condition is present, specific information can be found in the undervoltage self-test stuck-on or stuck-off debugging alerts.
Clear condition
Vehicle controller resets or successful Battery Domain Left Controller Undervoltage self-test.
Check other alerts
With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of VCLEFT_a413.