Alert Description
The low voltage battery management system (LVBMS) is reporting the low voltage (LV) battery's electronic connector position assurance (E-CPA) is not secure, which could result in the LV battery becoming disconnected from the rest of the vehicle electrical systems. This could occur due to the E-CPA locking tab not being fully pushed down, or communication issues between the LVBMS and vehicle controller.
Potential Impact
The LV battery may become (or may already be) disconnected from the rest of the vehicle electrical systems, which would make the LV battery unable to support vehicle electrical systems or to recharge via the power conversion system (PCS).
Set condition
The LVBMS is not communicating as expected with the vehicle controller (MIA) or reports the LV battery's E-CPA is not closed.
Clear condition
The LVBMS is communicating as expected with the vehicle controller (not MIA) and reports the LV battery's E-CPA is closed.