Skip to content

VCFRONT_a434 — T LVBMS Config Init Failed

Full alert identifier: VCFRONT_a434_TLVBMS_ConfigInitFailed

Alert description

The Battery Management System (BMS) firmware does not have config parameters for the desired/installed battery type

Potential impact

BMS firmware does not support the desired battery type and will not operate

Set condition

An unsupported battery type is installed

Clear condition

A supported battery type is installed

Signals to check

These diagnostic fields are associated with VCFRONT_a434. Check the alert's Payload in Service Mode Plus for available values.

Signal Unit
Bmb Module Id VCFRONT_a434_bmbModuleId —
Bmb Module Id Valid VCFRONT_a434_bmbModuleIdValid —
Cell Type Data VCFRONT_a434_cellTypeData —
Pack Type Data VCFRONT_a434_packTypeData —
Use Bmb Module Id VCFRONT_a434_useBmbModuleId —

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of VCFRONT_a434.

Browse all VCFRONT alert codes