VCFRONT_a274 — Failure To Precharge Risk2
Full alert identifier: VCFRONT_a274_failureToPrechargeRisk2
Alert description
Based on historical data, the vehicle controller determines there is a high probability the low voltage (LV) battery will not successfully precharge the high voltage (HV) bus. This alert is intended to capture LV battery conditions and assist with diagnosis if primary alert failureToPRechargeRisk cannot be logged by the vehicle Gateway (GTW) at time of initial occurrence due to LV undervoltage condition.
Potential impact
This information is not available in the alert reference.
Set condition
This information is not available in the alert reference.
Clear condition
This information is not available in the alert reference.
Signals to check
These diagnostic fields are associated with VCFRONT_a274. Check the alert's Payload in Service Mode Plus for available values.
| Signal | Unit |
|---|---|
Dcr Milli Ohms Above Threshold Trigger
VCFRONT_
|
— |
Dead LV Minimal Ah Discharged Trigger
VCFRONT_
|
— |
Instant Precharge DCR Too High Trigger
VCFRONT_
|
— |
Precharge LV Load Reduction Trigger
VCFRONT_
|
— |
Resistance Estimation Hard Fail Trigger
VCFRONT_
|
— |
Shorted Cell Test Trigger
VCFRONT_
|
— |
Volt Drop On High Current Trigger
VCFRONT_
|
— |
Check other alerts
With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of VCFRONT_a274.