VCFRONT_a271 — LV Battery Perm Supported
Full alert identifier: VCFRONT_a271_LVBatteryPermSupported
Alert description
After a Low Voltage (LV) Battery condition was identified that may prevent precharging the High Voltage (HV) Bus, the HV Bus successfully energized and will support the LV System to enable drive. The vehicle controller requests to keep the HV bus energized until the LV battery is replaced.
Potential impact
The HV System will remain on to support vehicle functions, including drive, and the HV contactors will remain closed.
Set condition
The failureToPrechargeRisk alert is set, and the HV Bus is energized.
Clear condition
The LV Battery is replaced.
Signals to check
These diagnostic fields are associated with VCFRONT_a271. Check the alert's Payload in Service Mode Plus for available values.
| Signal | Unit |
|---|---|
Dcr Milli Ohms Above Threshold Trigger
VCFRONT_
|
— |
Dead LV Minimal Ah Discharged Trigger
VCFRONT_
|
— |
Instant Precharge DCR Too High Trigger
VCFRONT_
|
— |
Precharge LV Load Reduction Trigger
VCFRONT_
|
— |
Resistance Estimation Hard Fail Trigger
VCFRONT_
|
— |
Shorted Cell Test Trigger
VCFRONT_
|
— |
Volt Drop On High Current Trigger
VCFRONT_
|
— |
Check other alerts
With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of VCFRONT_a271.