Skip to content

VCFRONT2_a470 — Implausible Pd Pl Detected

Full alert identifier: VCFRONT2_a470_implausiblePdPlDetected

Alert description

Difference between the discharge pressure and liquid pressure (Pd-Pl) increased. Discharge lines or Liquid Cooled Condenser (LCC) or Shut Off Valve (SOV) may be blocked.

Potential impact

Thermal performance is degraded.

Set condition

Pd-Pl is greater than 6 bar for 5 consecutive seconds.

Clear condition

Pd-Pl is less than 4 bar for 5 consecutive seconds.

Signals to check

Open this alert in Service Mode Plus and review the Payload tab. Use the field names below to identify the values shown by your vehicle.

Signal Unit
Pressure Discharge VCFRONT2_a470_pressureDischarge bar
Pressure Liquid VCFRONT2_a470_pressureLiquid bar

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of VCFRONT2_a470.

Browse all VCFRONT2 alert codes