Skip to content

VCFRONT2_a368 — Discharge Routine Exited

Full alert identifier: VCFRONT2_a368_dischargeRoutineExited

Alert description

HV Battery Discharge routine exited, the HV Battery Discharge will not run until reset conditions are met.

Potential impact

Refer to HV Battery Discharge routine documentation.

Set condition

System condition for the HV Battery Discharge routine are not met and the routine is exiting.

Clear condition

Will clear automatically

Signals to check

Open this alert in Service Mode Plus and review the Payload tab. Use the field names below to identify the values shown by your vehicle.

Signal Unit
Bms Soc VCFRONT2_a368_bmsSoc %
Signal Unit
Below Soc Min VCFRONT2_a368_belowSocMin —
Bms Request Removed VCFRONT2_a368_bmsRequestRemoved —
Coolant Not Filled VCFRONT2_a368_coolantNotFilled —
Coolant Pumps Faulted VCFRONT2_a368_coolantPumpsFaulted —
Coolant Temp Sensors Faulted VCFRONT2_a368_coolantTempSensorsFaulted —
Coolant Valve Faulted VCFRONT2_a368_coolantValveFaulted —
Entering State VCFRONT2_a368_enteringState
0
NOT READY
1
READY
2
BATTERY HEATING
3
BATTERY DISCHARGE
4
INHIBIT FOR REST
5
FAULTED
—
Exiting State VCFRONT2_a368_exitingState
0
NOT READY
1
READY
2
BATTERY HEATING
3
BATTERY DISCHARGE
4
INHIBIT FOR REST
5
FAULTED
—
Show 4 more fields
Signal Unit
Fans Faulted VCFRONT2_a368_fansFaulted —
Louver Faulted VCFRONT2_a368_louverFaulted —
Preconditions Not Met VCFRONT2_a368_preconditionsNotMet —
System Faulted VCFRONT2_a368_systemFaulted —

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of VCFRONT2_a368.

Browse all VCFRONT2 alert codes