Skip to content

VCFRONT2_a214 — Pt Pump Compromised

Full alert identifier: VCFRONT2_a214_ptPumpCompromised

Alert description

The brushless direct current motor has a condition affecting its functionality.

Potential impact

The Powertrain Pump will not be able to run.

Set condition

The Powertrain Pump motor driver detected a condition affecting its functionality.

Clear condition

The integrated circuit of the Powertrain Pump motor driver no longer detects a condition affecting its functionality.

Signals to check

These diagnostic fields are associated with VCFRONT2_a214. Check the alert's Payload in Service Mode Plus for available values.

Signal Unit
Bus Voltage Irrational VCFRONT2_a214_busVoltageIrrational —
Bus Voltage Unhealthy VCFRONT2_a214_busVoltageUnhealthy —
Chip Overtemp VCFRONT2_a214_chipOvertemp —
Dc Current Irrational VCFRONT2_a214_dcCurrentIrrational —
Dc Overcurrent VCFRONT2_a214_dcOvercurrent —
Ecu Reset VCFRONT2_a214_ecuReset —
Fet Temp Irrational VCFRONT2_a214_fetTempIrrational —
Hardware Overcurrent VCFRONT2_a214_hardwareOvercurrent —
Show 25 more fields
Signal Unit
Hs Vds Overvoltage VCFRONT2_a214_hsVdsOvervoltage —
Hs Vds Overvoltage Mask VCFRONT2_a214_hsVdsOvervoltageMask —
Lin Checksum Error VCFRONT2_a214_linChecksumError —
Lin Framing Error VCFRONT2_a214_linFramingError —
Ls Vds Overvoltage VCFRONT2_a214_lsVdsOvervoltage —
Ls Vds Overvoltage Mask VCFRONT2_a214_lsVdsOvervoltageMask —
Motor Control Error VCFRONT2_a214_motorControlError —
Motor Faulted VCFRONT2_a214_motorFaulted —
Motor Locked VCFRONT2_a214_motorLocked —
Motor Open Phase VCFRONT2_a214_motorOpenPhase —
Motor Overtemp VCFRONT2_a214_motorOvertemp —
Motor Phase Current Irrational VCFRONT2_a214_motorPhaseCurrentIrrational —
Motor Soft Open Phase VCFRONT2_a214_motorSoftOpenPhase —
Motor Speed Irrational VCFRONT2_a214_motorSpeedIrrational —
Motor Speed Too High VCFRONT2_a214_motorSpeedTooHigh —
Motor Stalled VCFRONT2_a214_motorStalled —
Over Voltage VCFRONT2_a214_overVoltage —
Payload Bits Not Set VCFRONT2_a214_payloadBitsNotSet —
Phase Overcurrent VCFRONT2_a214_phaseOvercurrent —
Phase Shorted VCFRONT2_a214_phaseShorted —
Self Test Failed VCFRONT2_a214_selfTestFailed —
Self Test Result VCFRONT2_a214_selfTestResult
0
NOT TESTED
1
SHORT SUPPLY
2
SHORT GROUND
3
OPEN PHASE U
4
OPEN PHASE V
5
OPEN PHASE W
6
UNKNOWN
7
PASSED
—
Supply Voltage Irrational VCFRONT2_a214_supplyVoltageIrrational —
Under Voltage VCFRONT2_a214_underVoltage —
Vdda Overcurrent VCFRONT2_a214_vddaOvercurrent —

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of VCFRONT2_a214.

Browse all VCFRONT2 alert codes