Skip to content

VCFRONT1_a165 — Unxpctd eFuse Lckout

Full alert identifier: VCFRONT1_a165_unxpctdEFuseLckout

Message shown in the car

Vehicle will consume more energy while idle Schedule service

Alert description

The front vehicle controller (VCFRONT) detects an eFuse lockout is active (via voltage measurement of the lockout circuit) when the right vehicle controller (VCRIGHT) is not reporting an eFuse lockout is active.

Potential impact

If the eFuse lockout circuit is enabled unexpectedly, VCFRONT cannot enable or disable the low voltage (LV) power feed to other controllers. Vehicle features and functions relying on power supply via VCFRONT may be unavailable. Vehicle software updates may not complete successfully.

Set condition

The VCFRONT detects voltage on the eFuse lockout circuit (nominal 5V on eFuse lockout circuit for 2 seconds) when VCRIGHT has not reported the lockout circuit as active.

Clear condition

The VCFRONT eFuse lockout circuit voltage measurement indicates an eFuse lockout is no longer active, and the VCRIGHT is not reporting an active eFuse lockout.

Signals to check

Open this alert in Service Mode Plus and review the Payload tab. Use the field names below to identify the values shown by your vehicle.

Signal Unit
Lockout Voltage VCFRONT1_a165_lockoutVoltage V

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of VCFRONT1_a165.