VCBATT2_a522 — Hibernation Active Log Capture
Full alert identifier: VCBATT2_a522_hibernationActiveLogCapture
Alert description
Vehicle will enter deep sleep to conserve energy in 10 minutes. It is possible to wake the vehicle up within the next 10 minutes by pressing the trunk button or applying external voltage to the front trunk (frunk) access posts.
Potential impact
Vehicle will only wake from deep sleep via a trunk button press or when external voltage is applied to the frunk access posts.
Set condition
The vehicle is in Transport Mode and the high voltage (HV) battery state of charge (SOC) is low.
Clear condition
HV battery SOC is above 20% and/or vehicle exits Transport Mode.
Signals to check
Open this alert in Service Mode Plus and review the Payload tab. Use the field names below to identify the values shown by your vehicle.
| Signal | Unit |
|---|---|
HV Soc
VCBATT2_
|
% |
IBS Voltage
VCBATT2_
|
V |
| Signal | Unit |
|---|---|
LV Battery Cannot Support Vehicle
VCBATT2_
|
— |
LV Battery Disconnected
VCBATT2_
|
— |
Contactors Permanently Closed
VCBATT2_
|
— |
Reverse Battery Fault
VCBATT2_
|
— |
Check other alerts
With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of VCBATT2_a522.