Skip to content

VCBATT2_a391 — Frunk Latch Switch Fault

Full alert identifier: VCBATT2_a391_frunkLatchSwitchFault

Alert description

Unexpected front trunk (frunk) latch switch values are present, which may result in the frunk state not matching the state indicated in the touchscreen user interface (UI).

Potential impact

The state of the front trunk (frunk) latch (open or closed) may be inaccurate. Front trunk (frunk) state may not match the state indicated in the touchscreen user interface (UI). For example, the UI may report the frunk as open when closed, or closed when open.

Set condition

Both front trunk (frunk) switches are pressed, or both frunk switches are unpressed, or any frunk switch is shorted / disconnected.

Clear condition

Front trunk (frunk) latch switch values are in expected range.

Signals to check

Open this alert in Service Mode Plus and review the Payload tab. Use the field names below to identify the values shown by your vehicle.

Signal Unit
Switch 1 Voltage Average VCBATT2_a391_switch1VoltageAverage mV
Switch 1 Voltage Instant VCBATT2_a391_switch1VoltageInstant mV
Switch 2 Voltage Average VCBATT2_a391_switch2VoltageAverage mV
Switch 2 Voltage Instant VCBATT2_a391_switch2VoltageInstant mV
Signal Unit
Switch 1 Disconnected VCBATT2_a391_switch1Disconnected —
Switch 1 Shorted VCBATT2_a391_switch1Shorted —
Switch 2 Disconnected VCBATT2_a391_switch2Disconnected —
Switch 2 Shorted VCBATT2_a391_switch2Shorted —
Switch Mismatch VCBATT2_a391_switchMismatch —

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of VCBATT2_a391.

Browse all VCBATT2 alert codes