Skip to content

VCBATT2_a227 — Rad Fan Compromised

Full alert identifier: VCBATT2_a227_radFanCompromised

Alert description

The brushless direct current motor has a condition affecting its functionality.

Potential impact

The Radiator Fan will not be able to run.

Set condition

The Radiator Fan motor driver detected a condition affecting its functionality.

Clear condition

The integrated circuit of the Radiator Fan motor driver no longer detects a condition affecting its functionality.

Signals to check

These diagnostic fields are associated with VCBATT2_a227. Check the alert's Payload in Service Mode Plus for available values.

Signal Unit
Bus Voltage Irrational VCBATT2_a227_busVoltageIrrational —
Bus Voltage Unhealthy VCBATT2_a227_busVoltageUnhealthy —
Chip Overtemp VCBATT2_a227_chipOvertemp —
Dc Current Irrational VCBATT2_a227_dcCurrentIrrational —
Dc Overcurrent VCBATT2_a227_dcOvercurrent —
Ecu Reset VCBATT2_a227_ecuReset —
Fet Temp Irrational VCBATT2_a227_fetTempIrrational —
Hardware Overcurrent VCBATT2_a227_hardwareOvercurrent —
Show 25 more fields
Signal Unit
Hs Vds Overvoltage VCBATT2_a227_hsVdsOvervoltage —
Hs Vds Overvoltage Mask VCBATT2_a227_hsVdsOvervoltageMask —
Lin Checksum Error VCBATT2_a227_linChecksumError —
Lin Framing Error VCBATT2_a227_linFramingError —
Ls Vds Overvoltage VCBATT2_a227_lsVdsOvervoltage —
Ls Vds Overvoltage Mask VCBATT2_a227_lsVdsOvervoltageMask —
Motor Control Error VCBATT2_a227_motorControlError —
Motor Faulted VCBATT2_a227_motorFaulted —
Motor Locked VCBATT2_a227_motorLocked —
Motor Open Phase VCBATT2_a227_motorOpenPhase —
Motor Overtemp VCBATT2_a227_motorOvertemp —
Motor Phase Current Irrational VCBATT2_a227_motorPhaseCurrentIrrational —
Motor Soft Open Phase VCBATT2_a227_motorSoftOpenPhase —
Motor Speed Irrational VCBATT2_a227_motorSpeedIrrational —
Motor Speed Too High VCBATT2_a227_motorSpeedTooHigh —
Motor Stalled VCBATT2_a227_motorStalled —
Over Voltage VCBATT2_a227_overVoltage —
Payload Bits Not Set VCBATT2_a227_payloadBitsNotSet —
Phase Overcurrent VCBATT2_a227_phaseOvercurrent —
Phase Shorted VCBATT2_a227_phaseShorted —
Self Test Failed VCBATT2_a227_selfTestFailed —
Self Test Result VCBATT2_a227_selfTestResult
0
NOT TESTED
1
SHORT SUPPLY
2
SHORT GROUND
3
OPEN PHASE U
4
OPEN PHASE V
5
OPEN PHASE W
6
UNKNOWN
7
PASSED
—
Supply Voltage Irrational VCBATT2_a227_supplyVoltageIrrational —
Under Voltage VCBATT2_a227_underVoltage —
Vdda Overcurrent VCBATT2_a227_vddaOvercurrent —

Check other alerts

With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of VCBATT2_a227.

Browse all VCBATT2 alert codes