VCBATT1_a593 — Vcleft Fast Blow Power Cutoff
Full alert identifier: VCBATT1_a593_vcleftFastBlowPowerCutoff
Message shown in the car
Unable to drive - Service is required Electrical system issue detected
Alert description
The front vehicle controller (VCFRONT) detects a sudden high power draw from the left vehicle controller (VCLEFT), causing the VCFRONT to power off the VCLEFT.
Potential impact
Vehicle may be unable to drive. Vehicle functions that depend on the VCLEFT (such as left side windows, doors, seat functions, and/or powered liftgate) may be unavailable or their performance may be affected.
Set condition
There is a sudden high power draw being observed on the VCLEFT that is outside of the defined operating threshold.
Clear condition
The VCLEFT is serviced, and the VCFRONT determines the VCLEFT power cutoff is no longer required.
Signals to check
Open this alert in Service Mode Plus and review the Payload tab. Use the field names below to identify the values shown by your vehicle.
| Signal | Unit |
|---|---|
Vcleft Cutoff Current Threshold
VCBATT1_
|
A |
| Signal | Unit |
|---|---|
Vcleft Cutoff E Fuse Fast Blow Type
VCBATT1_
|
— |
Vcleft Cutoff Max Count
VCBATT1_
|
— |
Vcleft Cutoff Timing Threshold Ms
VCBATT1_
|
— |
Check other alerts
With Service Mode Plus enabled, open Service Alerts → All. Review the other alerts for clues to the cause of VCBATT1_a593.